1. Introduction

This setup guide describes how to integrate a Behnke SIP 2.0 into an existing Behnke intercom setup. It is assumed that:

  • all devices have already been started,
  • the basic initial setup has been completed,
  • valid IP addresses have been assigned,
  • the web interfaces of all devices are reachable,
  • a Behnke indoor station with a Behnke Station in intercom mode has already been set up.

If this has not yet been done, the settings can be made using the setup guide

A Behnke door station calls two indoor stations at the same time

.

Recommendation: For this setup, it is strongly recommended to configure fixed IP addresses (static IP addresses) on all devices. This ensures that direct IP dialing and the camera connection keep working permanently and that the devices do not lose each other after a restart or a DHCP change.

2. Network overview

Device IP address
Behnke Station 192.168.50.85
Behnke indoor station 192.168.50.173
Behnke SIP 2.0 192.168.50.217
Camera of the SIP 2.0 192.168.50.182

Innestelle_mit_Behnke_Sprechstelle_2.0_E_Mit_ipadesse_A

3. Configuring the Behnke SIP 2.0

The Behnke SIP 2.0 does not support an intercom mode. The door station must therefore register itself as a SIP participant. In addition, direct IP dialing must be enabled.

3.1 Self-registration of the SIP 2.0

Menu:

Network → SIP settings

Make the following settings:

Setting Value
Account 100
Phone number / user name 100
Name 100
SIP authentication ID 100
SIP authentication PIN 100
SIP authentication domain 192.168.50.217
SIP registrar 192.168.50.217

Note: In this scenario, the SIP 2.0 registers at its own IP address. This allows the indoor station to reach the door station via direct IP dialing without requiring an external SIP server.

2.0_selbstanmeldung_

3.2 Enabling direct IP dialing

Menu:

Network → SIP settings

Enable the following setting:

  • Direct IP dialing: Active

2.0_Direkte_IP-anwahl

3.3 Checking the SIP registration

After saving the settings, the status screen of the SIP 2.0 should show the status "Registered".

2.0_Sipanmeldung

3.4 Storing the target number in the button

So that the SIP 2.0 can dial the indoor station directly via IP, the IP address of the indoor station must be stored in the button configuration.

Menu:

Select number

Enter the following number:

Button Number
Number 192.168.50.173

Note: Direct IP dialing only works if the IP address of the remote station remains unchanged. The use of static IP addresses is therefore strongly recommended.

2.0_Taste_Ipadresse_nummer

4. Configuring the Behnke indoor station

4.1 Setting the number of IP stations

Menu:

Intercom

Under IP stations, set the number to 1.

in_innestation__Sprechanlagenmenü

4.2 Adding the SIP 2.0

Then add the SIP 2.0 as a new station.

Innenstation_2.0_dazufügen

Make the following settings:

Setting Value
Type BT-IP 2 Generation
Name Serie 2.0
Number sip:192.168.50.217
IP address or host name 192.168.50.217
Access type Access
UDP code to open the access -
DTMF code to open the access 0
Visualized opening duration 5
Camera type Behnke Type A
IP address or host name of the camera 192.168.50.182
Camera user root
Camera password Admin
Preferred view Center

Innstelle_IP_anlegen_3

5. Function test

After completing the configuration, the following check should be performed:

  1. Trigger a call at the SIP 2.0.
  2. The indoor station should ring.
  3. The camera image of the SIP 2.0 should be displayed on the indoor station.
  4. The door opener function should be tested.

Important

The SIP 2.0 and the indoor station can be registered with an external SIP server at the same time. The self-registration of the SIP 2.0 described here does not affect the registration with another SIP server.


Note

Recommendation: For installations with direct IP dialing and a camera connection, fixed IP addresses should always be used. Note: Direct IP dialing only works if both devices are in the same network or if there is a suitable routing connection between the networks.

✕