{"wiki":"en","slug":"ringcentral","markdown":"<tags data-tags=\"SIP phone;PBXs;Configuration guides;\" />\n\n# Configuration guide RingCentral®\n\n## 1. Configuration guide\n\nThis configuration guide describes how to set up a Behnke Station as a SIP extension of a RingCentral® cloud PBX. We are assuming that the basic configuration of the RingCentral® system has already been done, and we will only describe the steps required to register the Behnke Station with RingCentral®. We also assume that the Behnke station has already been integrated into the network and can be accessed via the IP address in a browser.\n\n### 1.1. Configuring the Behnke Station\n\n- Open a new tab in your browser, enter the IP address of the Behnke Station in the address bar and log in.\n\n  ![Login screen of the Behnke Station's web interface](uploads/0e19099d61bed69f209b99605a3e670d/RingCentral_E_01.png)\n\n- Click on **\"SIP Phone\"** in the menu. Scroll down to **\"SIP account 1\"** and select the option **\"yes\"** for **\"Register\"**.\n\n  ![SIP account 1 in the \"SIP Phone\" menu of the Behnke Station](uploads/d648871fd0d4ee14b07a683ad4b81f62/RingCentral_E_02.png)\n\n- Then fill in the fields with your RingCentral® SIP credentials as follows and click **\"Save\"** on the left.\n\n   | Field Behnke Station        | Value RingCentral®                        |\n   | --------------------------- | ----------------------------------------- |\n   | Phone number / user name    | User name with **\"@sip.ringcentral.com\"** |\n   | User ID                     | Auth-ID                                   |\n   | Password                    | Password                                  |\n   | Server                      | sip40.ringcentral.com                     |\n   | Port                        | 5096                                      |\n   | Transmission protocol       | TLS                                       |\n   | Media encryption            | SRTP                                      |\n   | Force media encryption      | no                                        |\n   | Verify server certificates  | no                                        |\n  \n  If the registration was successful, the **\"Registration state\"** changes to **{+registered+}**.\n\n  ![Registration state \"registered\" in the Behnke Station's web interface](uploads/f99a43e32bec4ee66a3b24b1cefeb406/RingCentral_E_03.png)\n\n- Then click **\"Buttons\"** in the menu on the left. For the desired call button enter the extension number or phone number that is to be called when the button is pressed. Then click **\"Save\"** on the left.\n\n  ![Call number of a call button in the \"Buttons\" menu of the Behnke Station](uploads/b437a260ed4f8a68eda91bacef24d1ec/RingCentral_E_04.png)\n\n## 2. Trouble shooting\n\n## 3. Legal notices\n\n[Legal notices](legal notices)","lastModified":"2026-08-20T14:30:11+02:00"}