{"wiki":"en","slug":"dnake-a416-w","markdown":"<tags data-tags=\"Remote Stations;Setup Guides;\"/>\n\n# Setup Guide for the DNAKE Indoor Station A 416 W\n\n\nThis setup guide describes how to put a DNAKE indoor station A 416 W into operation together with a Behnke Station. The following assumes that the basic configuration of the DNAKE indoor station A 416 has already been completed, and we limit ourselves exclusively to the steps required to commission the Behnke Station. \n\n%[NOTE_REQUIRES_BASIC_SETUP](NOTE_REQUIRES_BASIC_SETUP)%\n\n**Related setup guide(s) and notes**\n\nThe DNAKE indoor station A416 W and the Behnke Station must be in the same network to enable direct communication. \n\n![Example setup DNAKE and Behnke Station](uploads/460a9e1cb148b7c23defef1de4e2edfc/Schematiche_Zeichnung_bt_an_dnake__003_.jpg.png)\n\nHelp with configuring a static IP address on the DNAKE indoor station A416 W can be found in <a href=\"Einstellung-Statischer-IP-Adresse-von-Dnake-und-Behnke-Station\">this setup guide</a>.\n\n<!-- block: einrichten-der-behnke-station -->\n## 1. Setting up the Behnke Station\n\n- Open your browser\n- Open the web interface of the Behnke Station\n- Log in\n\n![Behnke Station, web interface, login page](uploads/fba16dfa9b4ea2edc2e4d66bb5fe1815/Startbild.jpg)  \n\n- In the sidebar on the left, click the menu item %BS_MENU_VERBINDUNG%\n- Navigate to the section **Cancel connection**\n- Set the option **Automatically after opening the access** to the value **yes**\n\n![Behnke Station web interface, menu item Connection, section Cancel connection](uploads/d78b345a3168dc66d9324c8dfb9a7283/Verbindungen_Relais.png)  \n\n- In the sidebar on the left, click the menu item %BS_MENU_AKUSTIK%\n- Navigate to the section **IP audio**\n- Set the option **Expert settings** to the value **configure individually**\n\n![Behnke Station web interface, menu item Acoustics, section Expert settings](uploads/f895bf3319b6af5fb164189c45122871/audio_2.png)\n  \n- Further configuration options are displayed\n- Set the option **Receive gain** to the value **6 dB**\n\n![Behnke Station web interface, menu item Acoustics, section Expert settings, option Receive gain](uploads/8d8f3ffb7b0324cc83716ca5556b6113/audio_3.png)\n\n- In the sidebar on the left, click the menu item %BS_MENU_SIP_TELEFON%\n- Navigate to the section **SIP direct calls**\n- Set the option **Allow SIP direct calls** to the value **yes**\n\n![Behnke Station web interface, menu item SIP phone, section SIP direct calls, option Allow SIP direct calls](uploads/0a19ff8a44b0fb4c5f65a406986ad04b/sipdirekruf_mir_ja.png)  \n\n- Navigate to the section **SIP account 1** or **SIP account 2**\n- Set the option **Register** to the value **yes**\n\n- Use the assignments from the following table and enter the information in the corresponding input fields (in the section **SIP account 1**, or **SIP account 2** if applicable) of your Behnke Station.\n\n   | Behnke Station field             | Value   |\n   | -------------------------------- | --------------------- |\n   | Phone number/user name           | 100          |\n   | User ID                          | 100            |\n   | Password                         | 100           |\n   | Server                           | IP address of the Behnke Station |\n\n![Behnke Station web interface, menu item SIP phone, section SIP account 1](uploads/175ff0c51a7776f417f5a15ea04f6c25/Sip_einstellungen_ohn_Sipserver_hinweise.png)  \n\n- In the sidebar, click %BS_MENU_SPEICHERN_ROT%\n- Wait a moment until the Behnke Station is reachable again\n- If the registration is successful, the option **Registration status** changes to the value <b style=\"color: green\">registered</b>. If this is not the case, please check the previous steps again.\n\n![Behnke Station web interface, menu item SIP phone, section SIP account 1, option Registration status](uploads/2c9ed8ff4908c2a0039303c2a3c1257e/Am_sipserver_regestriert.png) \n\n- Navigate to the section **Early Media**\n- Set the option **For outgoing calls** to the value **reject**\n\n![Behnke Station web interface, menu item SIP phone, section Early Media, option For outgoing calls](uploads/bba223fe8e17aeef6b69fe4f1f7d6d12/early_media.png)  \n\n- In the sidebar on the left, click the menu item %BS_MENU_TASTEN%\n- Navigate to the section of the button to be configured, e.g. **Button 1**\n- Set the option **Action** to the value **Call**\n- Set the option **Phone number** to the IP address of your DNAKE device\n\n![Behnke Station web interface, menu item Buttons, section Button 1, option Phone number](uploads/df1e080a494f7cf27d857cfa7e5127ad/Taste_Ipadresse_anwahl.jpg)\n\n<!-- block: hinweise-zur-installation -->\n### Installation notes\n\n- Configure a static IP address for both devices or create a reservation based on the MAC address in your DNS server. This is important because the Behnke Station can only reach your DNAKE A416 W via direct IP dialing. Feel free to use our <a href=\"Einstellung-Statischer-IP-Adresse-von-Dnake-und-Behnke-Station\">corresponding setup guide</a>.\n- With group calls, an image preview is **not possible**.\n- Group calls with simultaneous connection of participants via a SIP server and via direct IP call are **not possible**.\n- If calls cannot be answered on the DNAKE indoor station, please reinstall the software.\n [Danke_A_461_Wiki.zip](uploads/e00ecadd8ad942793106c7faa14f5c03/Danke_A_461_Wiki.zip)\n\n<!-- block: faq -->\n## 2. FAQ\n\n%[NO_CONTENT](NO_CONTENT)%\n","lastModified":"2026-10-14T13:47:15+02:00"}